Emergency Lighting Inverter System
EL-H SERIES
5 Kwatt to 18Kwatt Specification

1.0 GENERAL
The emergency lighting inverter system is a single phase, continuous duty, seamless transfer inverter. The Series EL-H is designed to supply reliable, isolated, clean, regulated emergency power for emergency lighting and associated controls. An efficient ferro-resonant transformer, microprocessor controlled solid state PWM inverter and long lasting battery pack provide immunity to all line disturbances and power interruptions with no break in AC output power. Power factor correction and harmonic attenuation are provided.
The synchronous inverter produces a true uninterrupted output in any mode of operation. A self-diagnostic monitoring alarm system continuously advises system status.
|
INVERTER RATINGS |
EL 5000 EL 5400 EL 6000 EL 7000 EL 8000 |
5000 Watts 5400 Watts 6000 Watts 7000 Watts 8000 Watts |
EL10K EL12K EL14.5K EL15K EL16K EL18K |
10 KWatts 12 KWatts 14.5 KWatts 15 KWatts 16 KWatts 16 kWatts |
2.1 The maintenance bypass switch provides a means to repair and perform preventative maintenance without disruption of the load. The bypass switch is rated for the maximum Kva of the system.
3.0 STANDARDS The systems shall be designed in accordance with: American National Standards Institute (ANSI C57.110) Institute of Electrical and Electronic Engineers (IEEE 519-1992 and IEEE C62.41-1991) National Electric Code (NEC) National Fire Protection Association (NFPA Article 70) Underwriters Laboratories (U/L) 924,1449, 1778 FCC Article 15, Section J, Class A
3.1 Listings The system shall be listed to U/L standards UL924 and UL1778
4.0 INPUT SPECIFICATIONS
4.1 Input Voltage: 120, 208 or 240 or 277 vac 4.2 Operating Range: +10% to -15% 4.3 Frequency Range: Capture 57.5 Hz to 62.5 Hz. 4.4 Power Factor: Self correcting to >0.95 (approaching unity) 4.5 Input Harmonics: < 5% THD (total harmonic distortion) 4.6 Spike Attenuation: 3000:1, exceeds ANSI/IEE C62.41 category B3 waveform
5.0 OUTPUT SPECIFICATIONS
5.1 Sine Wave Voltage: Maximum 3% harmonic distortion, any single harmonic. 5.2 Output Voltage: 20, 208/120, 240/120, 277/120 5.3 K Factor: 30 or better. 5.4 Power Factor: Unity rated. 5.5 Harmonic Attenuation: Reflected load generated harmonics are attenuated 23dB at the input. 5.6 Regulation: Typically better than +3%.
6.0 kVA RATINGS
6.1 Output is also rated for computer type loads with switch mode power supplies. Kva = Kwatt * / 0.7
7.0 BATTERY
7.1 Standard run times are 90 minutes at full Kwatt load. Additional run time up to 72 hours is available. 7.2 Type: Sealed, maintenance free, gas recombinant, self venting, suspended electrolyte with no gel contaminant. 7.3 Charger: Two stage, temperature compensated, matched to the system. 7.4 Recharge Time: Typically 24 hours to full charge. 7.5 Buss Voltage: Float 2.27 VPC, final 1.75 VPC. Factory tested with specific inverter before shipping. 7.6 Projected Life: 5 years service.
8.0 PERFORMANCE
8.1 Overload Capability: 125% for ten minutes. 8.2 Surge Capability: 150% of rated output without need of static bypass. 8.3 Frequency Stability: +0.2 Hz. 8.4 Inner Winding Capacitance: 0.01 pF (primary to secondary coupling). 8.5 Common Mode: 120 dB (106 : 1 ground noise attenuation). 8.6 Transverse Mode: 70 dB (3160 : 1 line noise attenuation). 8.7 Reactive Power Correction: Load at .6 pf corrected to > 0.95 at input (automatically self correcting).
9.0 DISPLAY MONITORS AND DIAGNOSTICS
9.1 DISPLAY Auto Logging Analyzer 2020 ALA2020
9.2 ALARMS Alarms the following faults:
| |
On Battery Power |
Low Battery |
| |
Charger Failure |
On Bypass |
| |
High temp |
|
10.0 COMMUNICATIONS INTERFACE
10.1 Status and alarm port. Used for remote annunciation 10.2 SNMP compatible
11.0 ENVIRONMENTAL
11.1 Isolation: NEC article 250-5d, complies with this standard that specifies a separately derived power source. 11.2 Operating Temperature: 0 (32) to 40 (105) degrees Celsius (F). 11.3 Storage Temperature: -20 to 50 degrees Celsius. 11.4 Relative Humidity: 95% non-condensed. 11.5 Elevation: 5,000 feet, 1500 meters.
12.0 MTBF
12.1 Total System: 100,000 hours MIL Spec standard 217E. 12.2 Transformer: 200,000 hours. Mean Time to Repair: Less than one hour.
13.0 POWER DISTRIBUTION
13.1 Standard hard wired output 13.2 Optional Normally -OFF bus or Timed Normally (OFF-ON) bus 13.3 Optional circuit breaker assortment 120 to 277 vac
14.0 WARRANTY
14.1 All systems are guaranteed to be free from material defects and workmanship for a period 1 year following delivery. 14.2 Batteries are warranted for 15 years, pro-rated.
15.0 MAINTENANCE
15.1 Maintenance contracts provide start-up, training and required annual tests and documentation in accordance with NFPA article 70.
|